How to Clean the Harman PF100 Heater Here are step-by-step instructions pertaining to cleaning your Harman PF100 Pellet Heater. These guidelines are to be found in conjunction while using owner’s manual that came with your furnace. For those who have any concerns about the procedure please don’t hesitate to contact your local official dealer.

In order to maintain top efficiency it is vital to clean and vacuum the interior of the furnace 3 or 4 moments per lose season. The furnace is made very easy to clean and it should take approximately one hour to total. A thorough cleaning is required at the conclusion of each heat season.

Keep in mind that cleaning your insert and venting system is essential. This boosts heat output and keeps the furnace running at optimum efficiency. Many Harman traders offer total annual cleaning companies for their customers. Please read this entire guide before beginning. TOOLS YOU WILL NEED: Dust Cover up , Security Goggles Shop vacuum w/fine dust (HEPA) filter Common socket set or nut driver set Tooth remember to brush 3 to 4 paintbrush Small putty knife Fireside glass cleanser Paper towels Rubber gloves (soot really enters pores) Drop cloth Flashlight or drop light 5 in. lexible brush (for venting pipe) Burn weed scraper (included w/furnace) GUIDELINES BEFORE YOU START: Make sure the heater is completely away and great (and unplugged from electrical power! ). The furnace should be completely away before washing. Every part must be cool to the touch, including the pellets that are left in the burn up pot. Live pellets are a fire risk ” particularly if they get sucked into a vacuum cleaner. Yearly there are tales of house vacuums capturing fire simply by inadvertently slurping up hot ashes. Even worse still this is often the source of any house fireplace!

Hot ashes should be stored in a material container using a tight fitting cover. When the ashes are completely out they can be used like a soil conditioner for your lawn or back garden. Wear a dust mask! This is important! Need not foolhardy with regards to protecting the lungs. Have on a face mask and safety goggles. Specialist chimney sweeps wear both while executing cleaning duties. STEP #1: PREPARE THE EFFORT AREA Begin by placing a drop cloth on the ground in front of the furnace. Additionally you can use paper. Keep your equipment on the drop cloth so that you can wrap all of them in that and take them outside to get cleaning when you are done.

STEP #2: BRUSH YOUR EXTERIOR FROM THE BURN WEED Open the medial side access door (Fig. 1) and begin simply by removing loose soot debris from within the burn weed. Remove the flame guide and vacuum the ash through the burn pan and over a burn pan (Fig. 2). Fig. 2 Fig. one particular Fig. 3 Clean the burn off pot making use of the scraper provided (Fig. 3). Use the toned end with the scraper to remove the co2 from the burn pot. Additionally use a sludge hammer and an aligned tip attach driver to tap the deposits loose. STEP #3: CLEAN THE IN HOUSE OF THE LOSE POT You’ll now ought to clean lung burning ash from inside the burn off pot.

Eliminate the clean out dish under the burn pot by loosening both wing nuts holding home plate in place (Fig. 4). You many need to use pliers to ease the side nuts in the beginning. Vacuum all ash from your burn pot’s interior (Fig. 5). Fig. 6 Fig. 4 Fig. 5 Use your ring finger to brush away any ash that cannot be reached with all the nozzle with the vacuum (Fig. 6). Following cleaning, make certain the plate is fully sealed before hand tightening the wing nuts. (Note: Do not tighten the side nuts with pliers. ) STEP #4: REMOVE THE UPPR BAFFLE PLATE Remove the higher baffle platter from the firebox on the wall structure opposite the burn-pot.

To accomplish this, lift the cover dish up regarding 1/2 it will be taken out for cleaning (Fig. 7). Use the pointed end in the scraper and a brush to clean the heat exchanger lurking behind the cover, let the ashes fall into the ash baking pan. Clean the remainder of the within the burn holding chamber using the scraper, putty blade, brush and vacuum. Fig. 7 Second Baffle Plate: After all the scraping and brushing of ashes is complete you may remove and empty the ash pan. There is a second baffle dish located below the upper woofer plate that becomes attainable when the lung burning ash pan can be removed.

Tip the top of the cover frontward and lift up and out of the heater. Do a final clean-up of the baffle and vacuuming from the inside of the firebox area as well as the ash skillet (ashes noted by decrease right arrow on Fig. 7). Exchange the abri plates being sure they are firmly latched in to position. Also, be sure the flame guidebook is substituted on the lose pot. Substitute the lung burning ash pan, close and latch the firebox door and out of doors cover door. STEP #5: REMOVE THE COMBUSTION MOTOR First, remove the combustion blower cover. The combustion blower real estate is held in place with two change latches (Fig. ). Up coming, remove the combustable motor frist by loosening the three thumb screws (Fig. 9). You can then twist the motor unit assembly counter-clockwise to remove it. NOTE: The motor wire connections do not need to always be disconnected. Fig. 8 Fig. 9 STEP #6: BRUSH YOUR COMBUSTION ENGINE , ENCIRCLING AREA When the combustion blower is taken out, the inside from the combustion blower area (Fig. 10) should be brushed and vacuumed. Subsequent, the fins of the combustion blower (Fig. 11) will require detailed washing as they will accumulate sooty dust.

Even though the combustion lover is displayed removed in this view to get clarity (Fig. 12), you don’tneed to detach the wiring of the motor unit for this stage. The fins of the blower need to be properly cleaned with a toothbrush. Be extra careful not to bend the bout on the burning blower because this may trigger an disproportion or interference with the inside the blower enclosure when it is reman. Fig. 12 Fig. 10 Fig. doze STEP #7: CLEAN THE DRILL DRIVE PACKAGE The next step is to wash the inside of the pellet give food to mechanism and a general clean-up “under the hood from the furnace.

Start with removing the top sheet-metal cover under the pellet hopper (Fig. 13). There are four anchoring screws holding this kind of cover in place, two can be found as observed in the image in fig. 13. The other two screws are on lack of of the furnace. You need simply to loosen the screws a number of turns and slide the cover away. Fig. 13 Under the cover you will find the feeder assembly, you need to remove the wing nut in the heart of the enclosure cover (Fig. 14) and remove the cover. After getting rid of the cover, clean out the inside of the housing (Fig. 15) with a tiny brush and a vacuum.

Change the drill assembly cover and wing nut after which the outer piece metal cover. Tighten the sheet metallic cover anchoring screws snuggly and then you’re done cleaning the “engine housing. Fig. 14 Fig. 15 STAGE #8: CLEAN OR EXCHANGE THE AIR FILTRATION You will need to clean or replace the air filtration on the filtration box (Fig. 16). The actual air filter manufacturer’s instructions to get cleaning or perhaps replacement. Filter systems are widely available at components stores and home centers. Fig. 16 STEP #9: SWEEP THE COMPLETE FLUE SYSTEM It is very important which the entire flue system is checked out and cleansed once each year.

In order to brush your flue program you will need to spread around it from its exit stage using rods and an appropriately sized brush. You may have to take apart parts of pipe in order to do this. Be aware: Professional contractors often design and style the air flow system in order that certain bones can be used apart. These types of joints will often have either aluminum tape or perhaps silicone caulking on the outside. Use a knife to scrape off the silicone covering on the joints you plan for taking apart. In case your pellet stove is mounted into an existing chimney you need to clean the chimney as well as the pellet pipe.

To get this done you will need the appropriate sized fireplace brush and rods. (i. e. a six inch diameter chimney will need a 6 diameter brush) As soon as the flue program has been cleaned out, reconnect and recaulk the pellet vent out. High temperature RTV silicone caulking will work for this. Note: it is crucial that each joint of the water pipe within the house be foolproof. Even small pinhole leaks can outflow smoke! If you have any queries regarding any kind of aspect of these cleaning guidelines, please pertain back to your Owner’s Manual or contact your authorized Harman dealer.